Choose a chimney system suited to your heating appliance
A chimney system carries flue gases from a heating appliance to the outside. Choosing the right system starts with the appliance, the building and the installation route. HENITOM offers single-wall, insulated and air/flue-gas systems made from austenitic steel. The families below group the available solutions and explain the system codes, helping you compare options before discussing the technical details with our team.
![Air/flue chimney system [SKS]](https://htyaxnmmpwuadnddpxyi.supabase.co/storage/v1/object/public/site-media/categories/84185ef8-cc83-43aa-8aa9-671e170bd417.webp)
Air/flue chimney system [SKS]
For gas-, oil- and pellet-fired appliances with a sealed combustion chamber. The single-wall construction with seals ensures a leak-tight flue. The system removes flue gases, while combustion air is supplied through a separate duct. Flue-gas temperature: up to 200°C.
![Concentric air/flue chimney system [SKSP]](https://htyaxnmmpwuadnddpxyi.supabase.co/storage/v1/object/public/site-media/categories/dc9566f8-6f0b-4a72-80d4-a6192df5a0a8.webp)
Concentric air/flue chimney system [SKSP]
For gas-, oil- and pellet-fired appliances with a sealed combustion chamber. The concentric twin-wall construction with seals provides a leak-tight flue. Flue gases are discharged through the inner pipe, while combustion air is supplied through the annular space between the pipes. Flue-gas temperature: up to 200°C.

Air/flue kits
For gas-, oil- and pellet-fired appliances with a sealed combustion chamber. Complete air/flue kits tailored to specific appliances and connection arrangements. A practical solution for installers, distributors and heating-appliance retailers. Flue-gas temperature: up to 200°C.
![Insulated air/flue chimney system [SKSPI-2]](https://htyaxnmmpwuadnddpxyi.supabase.co/storage/v1/object/public/site-media/categories/30a808f4-1228-49ae-8084-bd5b6ad33c84.webp)
Insulated air/flue chimney system [SKSPI-2]
For gas-, oil- and pellet-fired appliances with a sealed combustion chamber. The insulated twin-wall construction with seals ensures a leak-tight flue. Flue gases travel through the inner pipe, while combustion air is supplied by a separate duct. The system enables the construction of a free-standing insulated chimney, including outside the building. Flue-gas temperature: up to 200°C.
![Insulated air/flue chimney system [SKSPI-3]](https://htyaxnmmpwuadnddpxyi.supabase.co/storage/v1/object/public/site-media/categories/8fbb430e-1cb8-4c66-9077-b4db29fcbc6f.webp)
Insulated air/flue chimney system [SKSPI-3]
For gas-, oil- and pellet-fired appliances with a sealed combustion chamber. The insulated triple-wall construction with seals ensures a leak-tight flue. Flue gases are discharged through the inner pipe, while the space between the walls supplies combustion air. The system allows a free-standing insulated chimney to be built, including outdoors. Flue-gas temperature: up to 200°C.

Single-wall round chimney system
A single-wall round chimney liner made of 1.4404 acid-resistant steel, installed inside an existing chimney shaft. Intended for compatible appliances using pellets, wood, coal, eco-pea coal, gas and heating oil. Used to modernise and protect the chimney against flue gases and condensate. Flue-gas temperature: up to 600°C.

Single-wall oval chimney system
A single-wall oval chimney liner made of 1.4404 acid-resistant steel, installed inside an existing chimney shaft. Intended for compatible pellet-, wood-, coal-, eco-pea-coal-, gas- and oil-fired appliances. The oval shape makes efficient use of the cross-section of rectangular chimney flues. Flue-gas temperature: up to 600°C.

Insulated twin-wall chimney system
An insulated twin-wall chimney system made of 1.4404 acid-resistant steel for constructing standalone chimneys, including outside a building. For compatible appliances using pellets, wood, coal, eco-pea coal, gas and heating oil. The 50 mm insulation layer reduces flue-gas cooling and helps maintain the correct chimney draught. Flue-gas temperature: up to 600°C.

Chimney system for saunas, hot tubs and jacuzzis
A chimney system for saunas, hot tubs and jacuzzis assembled from single-wall SK and insulated SKI components, depending on the appliance and installation conditions. Intended for venting flue gases from wood- and briquette-fired stoves. It also includes protective sleeves and special made-to-measure components tailored to the specific installation.
Proven steel. Safety and precision manufacturing.

AUSTENITIC STEEL
1.4301 - AISI 304 · 1.4404 - AISI 316L

COMPLIANCE WITH STANDARDS
Tested systems with CE marking.

SAFE OPERATION
Correct selection for the appliance and operating conditions.

STANDARD AND MADE-TO-MEASURE SOLUTIONS
Tailored to each installation.
Start with the appliance, fuel and operating conditions
What type of heating appliance do you have?
Specify the type of boiler, fireplace or stove and its technical parameters.
Which fuel is used?
Gas, heating oil, pellets, wood (including holzgas), coal or eco-pea coal.
Where will the chimney run?
Inside an existing chimney shaft, within the building or outside?
What are the installation’s operating conditions?
Flue-gas temperature, flue diameter and height, draught and the potential for condensate formation.
Product families
01Air/flue systems
SKS · SKSP · KOMINSET
02Insulated air/flue systems
SKSPI-2 · SKSPI-3
03Single-wall chimney systems
SK · SKO
04Insulated chimney systems
SKI
05Systems for saunas and jacuzzis
SK SKI
Frequently asked questions
Do acid-resistant chimney systems require condensate drainage?+
Condensing appliances normally require correctly designed condensate collection and drainage. Our technical team will confirm the right arrangement for your appliance and route.
Which systems are suitable for gas condensing boilers?+
SKS, SKSP and insulated SKSPI variants are designed for modern closed-combustion appliances operating in positive pressure, subject to the project specification.
Can I install the chimney system myself?+
Installation should follow the system documentation and applicable regulations. For safety, we recommend a qualified installer and final system inspection.
How do I choose the chimney diameter?+
Diameter depends on appliance output, fuel, flue temperature, usable height and route. Send us these parameters and we will help select the system.
Consult our expert